meter(TDS-100F)

meter(TDS-100F)
Product Detailed
Related Categories:Flow Meters

Detailed Product Description


TDS-100F is a fixed mounted ultrasonic flow meter,and can operate with all HIPEAK instruments transducer. Their electronic enclosures are rated as IP65 (NEMA 4X), thus, can be installed for both indoor and outdoor.

Item

Performance, Parameters

Accuracy

Better than ±1.0 %

Repeatability

0.2%

Velocity

±32m/s

Measurement Period

0.5S

Measurement

Principle

Transit-time measurement principle

Display

LCD with backlight. 2x20 letters.

Keypad

4x4-key membrane keypad with tactile feedback

Input

Five channel 4-20mA current inputs for signals such as temperature, pressure, liquid level, and etc.. Accuracy 0.1%.

Two of the five input channels are wired to terminal blocks. The remaining three channels are optional.

Outputs

Analogue output: 4-20mA or 0-20mA current output. Impedance 01kΩ.

Isolated OCT output: for frequency output (0-9,999Hz), alarm driver, or totaliser pulse output, ON/OFF control, etc.

Relay output 1A@125VAC or 2A@30VDC. For ON/OFF control, alarm driver, totaliser output, etc.

Internal Alarm (Buzzer): user programmable.

External Alarm Driver: alarm signal can be transmitted to Relay or OCT output terminals to drive an external alarm.  

RS-232 serial port.

Others

Capable of offline compensation for flow totaliser, automatic / manual selectable. Self-diagnosis.

Automatically record the following information:

The totaliser data of the last 64 days / 64 months / 5 years;

The power-on time and corresponding flow rate of the last 64 power on and off events. Allow manual or automatic flow loss compensation

The instrument working status of the last 64 days

Power

AC: 220VDC: 8~36VDC or AC7-30V

Power Consumption

< 2W

Work time

Continuous

Environment

Temperature

-30-80 Degrees Celsius

Environment

Humidity

85% RH